  phasecap hd capacitors for power factor correction mkk-series series/type: mkk440-d-56-21 ordering code: B25669B4927J375 date: 2005-12-14 version: 3 content of inside pages of data sheet. data will be automatically entered into frontpage headlines, headers and footers. please fill in the table and then change the colour to ?white?. this ensures that the table disappears for the customer pdf. identification/classification 1: (header 1) phasecap hd capacitors for power factor correction identification/classification 2: (header 2) mkk-series ordering code: B25669B4927J375 series/type: mkk440-d-56-21 preliminary data (optional): (if necessary) department: fk pfc r&d date: 2005-12-03 ? epcos ag 2005. reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without epcos' prio r express consent is prohibited.
phasecap hd capacitors for power factor correction B25669B4927J375 mkk-series mkk440-d-56-21 construction ? ? ? ? ? ? ? ? ? dielectric: polypropylene film gas-impregnated / dry type wave cut extruded round aluminum can with stud triple safety system features three phase, delta connected self-healing technology naturally air cooled (or forced air cooling) indoor mounting technical data and specifications characteristics rated capacitance c r 3 x 307 f tolerance -5 / +10% connection d (delta) rated voltage v r 440 vac rated frequency f r 50 hz 60 hz output 56 kvar ---- rated current i r 74 a ---- tan (dielectric) 0.2 w / kvar maximum ratings v max (up to 8 h daily) 480 vac v max (up to 1 min) 570 vac i max 1.3 x i r (a) i s 200 x i r (a) test data v tt 950 vac / 50 hz during 10 s v tc 3000 vac / 50 hz during 10 s tan (50 hz) 0.45 w / kvar fk pfc r&d 2005-12-03 please read the important notes on page 7 page 2 of 7 and the cautions and warnings.
phasecap hd capacitors for power factor correction B25669B4927J375 mkk-series mkk440-d-56-21 climatic category / -40/d t min (-) 40 oc t max (+) 55 oc humidity av. rel. < 95% maximum altitude 4000 m mean life expectancy t ld up to 130000 hours max. 5000 switching per year acc. to iec 60831 design data dimensions ( ? x l) 142 x 355 mm weight approx 4.7 kg impregnation dry, inert gas fixing threaded bolt m12 max. torque (al can stud) 10 nm mounting position upright. see ?maintenance and installation manual? for further details. terminals degree of protection isolated terminals ip20 max. torque 2.5 nm terminal cross section 35 mm 2 maximum terminal current 100 a creepage distance 15 mm clearance 12 mm safety mechanical safety overpressure disconnector max. short circuit current (afc: 10 ka) discharge resistor time 1 min (75 v) reference standards iec 60831-1/2. ul 810-5 th edition dimensional drawing label design fk pfc r&d 2005-12-03 please read the important notes on page 7 page 3 of 7 and the cautions and warnings.
phasecap hd capacitors for power factor correction B25669B4927J375 mkk-series mkk440-d-56-21 cautions and warnings ? in case of dents of more than 2 mm depth or any other mechanical damage, capacitors must not be used at all. ? to ensure the full functionality of the overpressure disconnector, elastic elements must not be hindered and a minimum space of 5 cm has to be kept above each capacitor. ? do not handle the capacitor before it is discharged to max. 10% of rated voltage. ? resonance cases must be avoided by appropriate application design in any case. ? handle capacitors carefully, because they may still be charged even after disconnection due to faulty discharging devices. ? protect the capacitor properly against over current and short circuit. ? failure to follow cautions may result, worst case, in premature failures, bursting and fire. discharging capacitors must be discharged to a maximum of 10% of rated voltage before they are switched in again. this prevents an electric impulse discharge in the application, influences the capacitor?s service life and protects against electric shock. the capacitor must be discharged to 75 v or less within 3 minutes. there must be not any switch, fuse or any other disconnecting device in the circuit between the power capacitor and the discharging device. discharge resistors are included in the extend of delivery; alternatively discharge reacto rs are available from epcos. discharge and short circuit capacitor before handling! service life expectancy electrical components do not have an unlimited servic e life expectancy; this applies to self-healing capacitors too. the maximum service life expectancy may vary depending on the application the capacitor is used in. safety ? ensure good, effective grounding for capacitor enclosures. ? provide means of disconnecting and insulating a faulty component/bank. ? handle capacitors carefully, because they may still be charged even after disconnection due to faulty discharging devices. ? the terminals of capacitors, connected bus bars and cables as well as other devices may also be energized. ? follow good engineering practice. overcurrent and short circuit protection ? use hrc fuses or mccbs for short circuit protection. short circuit protection and connecting cables should be selected so that 1.5 times the rated capacitor current can be permanently handled. ? hrc fuses do not protect a capacitor against overload - they are only for short circuit protection. ? the hrc fuse rating should be 1.6 to 1.8 times rated capacitor current. ? do not use hrc fuses to switch capacitors (risk of arcing). ? use thermal magnetic overcurrent relays for overload protection. fk pfc r&d 2005-12-03 please read the important notes on page 7 page 4 of 7 and the cautions and warnings.
phasecap hd capacitors for power factor correction B25669B4927J375 mkk-series mkk440-d-56-21 resonance cases resonance cases must be avoided by appropriate application design in any case. maximum total rms capacitor current (incl. fundamental harmonic cu rrent) specified in technical data must not be exceeded. overtemperature exceeding maximum allowed temperature may set the safety device out of operation. overpressure disconnector to ensure full functionality of an overpressure di sconnector, the following must be observed: 1. the elastic elements must not be hindered, i.e. - connecting lines must be flexible leads (cables), - there must be sufficient space (min. 5 cm) for expansion above the connections (see ?clearing distance for overpressure disconnector?). - folding beads must not be retained by clamps. 2. maximum allowed fault current of 10000 a in accordance with ul 810 standard must be assured by the application. 3. stress parameters of the capacitor must be within the iec60831 specification. re-switching vs. phase-opposition in case of voltage interruption, a sufficient discharge time has to be ensured to avoid phase- opposition and resulting high inrush currents . vibration resistance the resistance to vibration of capacitors corresponds to iec 68, part 2?6. max. test conditions: test duration 2 h frequency range 1 0 ... 55 hz corresponding to max. 0.7 g displacement amplitude 0.75 mm these figures apply to the capacitor alone. because the fixing and the terminals may influence the vibration properties, it is necessary to check stability when a capacitor is built in and exposed to vibration. irrespective of this, you are advised not to locate capacitors where vibration amplitude reaches the maximum in strongly vibrating equipment. mechanical protection the capacitor has to be installed in a way that mechanical damages and dents in the aluminum can are avoided. fk pfc r&d 2005-12-03 please read the important notes on page 7 page 5 of 7 and the cautions and warnings.
phasecap hd capacitors for power factor correction B25669B4927J375 mkk-series mkk440-d-56-21 clearing distance for overpressure disconnector above each capacitor, a minimum space of 5 cm has to be kept. this will enable a longitudinal extension of the can to secure the over-pressure disconnector work. grounding the threaded bottom stud of the capacitor has to be used for grounding. in case grounding is done via metal chassis that the capacitor is mounted to, the layer of varnish beneath the washer and nut should be removed. the maximum tightening torque is 10 nm. maintenance ? check tightness of the connections/terminals periodically. ? take current reading twice a year and compare wi th nominal current. use a harmonic analyser or true effective rms-meter. ? in case of current above the nominal current check your application for modifications. ? if a significant increase in the amount of non-linear loads has been detected, then a consultant has to be called in for a harmonic study. ? in case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. ? check the discharge resistors/reactors and in case of doubt, check their function: (1) power the capacitor up and down. (2) after 60 seconds the voltage between the terminals must decline to less than 50 v. ? check the temperature of capacitors directly after operation for a longer period, but make sure that the capacitors have been switched off. in ca se of excessive temperature of individual capacitors, it is recommended to replace these capacitors as this should be an indication for loss factor increase which is a sign for reaching end of life. storage and operating conditions do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. in dusty environments regular maintenance and cleaning especially of the terminals is required to avoid conductive path between phases and/or phases and ground . note for detailed information about pfc capacitors and cautions, refer to the latest version of epcos pfc product profile. fk pfc r&d 2005-12-03 please read the important notes on page 7 page 6 of 7 and the cautions and warnings.
important notes the following applies to all products named in this publication: 1. some parts of this publication contain statements about the suitability of our products for certain areas of application . these statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. we nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. as a rule, epcos is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. for these reasons , it is always ultimately incumbent on the customer to check and decide whether an epcos product with the properties described in the product specification is suitable for use in a particular customer application. 2. we also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. in customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving system s), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. the warnings, cautions and product-specific notes must be observed. 4. in order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as ?hazardous?) . useful information on this will be found in our material data sheets on the internet (www.epcos.com/material). should you have any more detailed questions, please contact our sales offices. 5. we constantly strive to improve our products. consequently, the products described in this publication may change from time to time . the same is true of the corresponding product specifications. please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. we also reserve the right to discontinue production and delivery of products . consequently, we cannot guarantee that all products named in this publication will always be available. 6. unless otherwise agreed in individual contracts, all orders are subject to the current version of the ?general terms of delivery for products and services in the electrical industry? published by the german electrical and electronics industry association (zvei) . 7. the trade names epcos, ceradiode, cssp, phasecap, phasemod, sifi, sikorel, silvercap, simid, siov, sip5d, sip5k, topcap, ultracap, windcap are trademarks registered or pending in europe and in other countries. further information will be found on the internet at www.epcos.com/trademarks. page 7 of 7


▲Up To Search▲   

 
Price & Availability of B25669B4927J375

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X